I-7570

  • Support HART Short / Long frame
  • Support HART Burst mode
  • Support point-to-point or multi-drop HART mode
  • Support connecting up to 15 HART slave devices
  • Allow two HART masters
  • Provide utility tool for module configuration and HART communication
  • 4KV ESD Protection
  • Built-in Watchdog
  • Selectable 250Ω load resistor
  • Support HART OPC Server provided by HART COMMUNICATION FOUDATION

Introduction

I-7570 is a Serial to HART converter and can be used as a HART master with HC_Tool utility or a HART slave with HDS utility.

(1) I-7570 as HART Master :

It allows users to access the HART slave by using RS-232 / RS-422 / RS-485. These HART slave devices may be a transmitter, actuator, current output device and so forth. In addition, by using the I-7570 utility tool, users can configure module and test HART communication easily and quickly.

(2) I-7570 as HART Slave :

HART Device Simulator (called HDS) is the HART device simulation software developed by ICP DAS. It can be used to simulate multi HART slave devices simultaneously to exchange data with HART master device by using ICP DAS HART converter (like: I-7567 / I-7570 / I-7547) connected to any COM port (USB / 232 / 485 / Ethernet). By this way, users can develop or verify the HART master program without any HART slave device.

HDS (HART Device Simulator) 

Application

  • Current Measuring
  • Petrochemical Industry Application
  • Environment Monitoring
  • Tunnel Monitoring
  • Monitor system
  • Building Monitoring

Specifications

 LED Indicators
 Status PWR / TxD / RxD

 

 COM Ports
 Ports RS-232(Tx / Rx / GND) / RS-422 / RS-485
9-pin screwed terminal block
 Baud Rate 1200 bps (For FW_v1.1)
1200 ~ 115200bps (For FW_v1.1 / HW_v1.2)
 Data Format O(odd parity), 8(data bit), 1(stop bit) (For FW_v1.1)
N/O/E(parity), 8(data bit), 1/2(stop bit) (For FW_v1.1 / HW_v1.2)

 

 HART
 Ports 1
 Protocol 2-pin screwed terminal block

 

 Power
 Reverse Polarity Protection Power reverse polarity protection, Over-voltage brown-out protection
 Input Range Unregulated +10 ~ +30 VDC
 Consumption 1 W

 

 Mechanical
 Dimensions (mm) 123 x 72 x 35 (H x W x D)
 Installation DIN-Rail or Wall Mounting

 

 Environment
 Operating Temperature -25 ~ +75 °C (-13 to 167 ℉)
 Storage Temperature -30 ~ +85 °C (-22 to 176 ℉)
 Humidity 5% ~ 95% RH, Non-condensing

 

Description

 PRODUCT SERIES     DESCRIPTION    QTY   INQUIRY
 I-7570     CR  Serial To HART Converter (Gray Cover) (RoHS) 1